Article Subject
Pharmacy
Abstract

A Simple fast and precise reversed phase high performance liquid chromatographic method is developed for the Deflazacort drug. Chromatographic separation was performed a C18 column (250×4.6 mm) as a stationary phase with the mobile phase of Acetonitrile, methanol and water (90:5:5 v/v). Flow rate is 1.0 ml/min the detection of wave length is 230 nm. This method was validated for linearity, accuracy, precision, LOD & LOQ as per the guidelines of ICH. The percentage of recovering was 98.8.The developed method was applied successfully for determination of Deflazacort is pharmaceutical dosage form.

Keywords
High performance liquid Chromatographic method
Deflazacort
ICH
Stationary Phase
Article PDF
PDF (For Download)